Assessment Of Radiation Dose During CT Brain

Abstract

The purpose of this study to assessment radiation dose of CT scanner on

brain by calculate effective dose , then to confirm is there any difference

between effective dose of male brain and female brain according to

differences at anatomical structure of male brain and female brain , and to

determine typical parameter that help to reduce overdose .

This study performed in Modern Medical Center , the study showed

amount of average effective dose (1.26756002 mSv ± 0.2 mSv ) and it's

not equal or above than standard effective dose of brain (2 mSv) that

recommended by ICRP . Also there is no any difference between

effective dose of male brain and female brain according to differences at

anatomical structure of brain .The typical parameter of (Kvp and mAs ) is  

(120 Kvp) and (60 mAs -100 mAs) for adult and pediatric

Overall Rating

0

5 Star
(0)
4 Star
(0)
3 Star
(0)
2 Star
(0)
1 Star
(0)
APA

Ahmed, M (2021). Assessment Of Radiation Dose During CT Brain. Afribary. Retrieved from https://afribary.com/works/assessment-of-radiation-dose-during-ct-brain

MLA 8th

Ahmed, Musab "Assessment Of Radiation Dose During CT Brain" Afribary. Afribary, 19 May. 2021, https://afribary.com/works/assessment-of-radiation-dose-during-ct-brain. Accessed 25 Nov. 2024.

MLA7

Ahmed, Musab . "Assessment Of Radiation Dose During CT Brain". Afribary, Afribary, 19 May. 2021. Web. 25 Nov. 2024. < https://afribary.com/works/assessment-of-radiation-dose-during-ct-brain >.

Chicago

Ahmed, Musab . "Assessment Of Radiation Dose During CT Brain" Afribary (2021). Accessed November 25, 2024. https://afribary.com/works/assessment-of-radiation-dose-during-ct-brain