Electromagnetic Distance Measurement (EDM) equipment is calibrated on a base to determine
instrument constants and errors. A series of measurements on a base can also be used to check
the performance and reliability of the instrument over time and to assess its precision against
the manufacturer's specifications. This research work, the establishment of Electromagnetic
Distance Measurement (EDM) calibration base entails the setting up of a functional base where
calibration of electromagnetic distance measurement (EDM) equipment can be carried out
within the institution. Two (2) monuments were re-established; including the existing three (3)
making it a total of five (5) monuments and subdivided into four bays and subsequently carried
out distance observations. Consequently, the measured distances for each of the bays were
entered into the Least Squares Method of Adjustment using the Matrix Laboratory (MATLAB)
and its instrument constant obtained.
Omin, E. (2018). Establishment of Electromagnetic Distance Measurement (EDM) Calibration Base. Afribary. Retrieved from https://afribary.com/works/final-year-project-on-edm-calibration-base
Omin, Ekima "Establishment of Electromagnetic Distance Measurement (EDM) Calibration Base" Afribary. Afribary, 21 Apr. 2018, https://afribary.com/works/final-year-project-on-edm-calibration-base. Accessed 24 Nov. 2024.
Omin, Ekima . "Establishment of Electromagnetic Distance Measurement (EDM) Calibration Base". Afribary, Afribary, 21 Apr. 2018. Web. 24 Nov. 2024. < https://afribary.com/works/final-year-project-on-edm-calibration-base >.
Omin, Ekima . "Establishment of Electromagnetic Distance Measurement (EDM) Calibration Base" Afribary (2018). Accessed November 24, 2024. https://afribary.com/works/final-year-project-on-edm-calibration-base